Supermarket  Case Studies





01 Background

One of major supemarket chains in Japan. This supermarket chain owns 660 stores nation wide.





02 The Challenge

In order to provide a better environment for shoppers, the management team asked for mean illuminance 1,000 lx at 13.3 feet high but the glare must be reduced to minimum (UGR < 16 or even lower). Several major brands have failed to achieve that goal.

Original Luminaires
Luminaires Used:T5 (Double Tubes)
UGR:23
Input Energy:28 W x 2 = 56 W
Flux : 2,640 lm x 2 = 5280 lm
Efficiency : 94 lm/W
Lifespan : 12,000 hours
Total Energy Consumed:T5 x 650 pcs = 3,432,000 W









03 The Solution



Mean Illuminance
Mean Illuminance:1100 lx
( Suggestion : 1000 lx up )
UGR:Suggestion < 16

04 Plan View

Marketplace area:30 x 30 m
Marketplace height:4 m
 UGR:< 10

Luminaires Used  L16N
Input Energy:16 W
Flux:2000 lm
Efficiency : 125 lm/W
Lifespan : 87,600 hrs
Total Energy Consumed:L16N x 720 pcs = 11,520 W

05 The Benefit

XLEDIAlized
Energy Saved 36 %

18,200 W → 11,520 W

UGR < 23 → UGR < 10

TOP